Getting started: can the data determine my parameters?
Source:vignettes/get-started.Rmd
get-started.RmdYou have a PK model and a plan for sampling. Before the study, or before a fit that will not converge, you want to know three things: can the parameters be determined at all, how precisely will this design estimate them, and what would help. This page answers them for one model, in the order you would ask. All output below comes from running the code.
1. Describe what is observed and what is known
pkident takes an rxode2 model with three extra pieces of information,
because the answer depends on them: which quantity is
observed (outputs), how the dose enters
(doses), and which values are known
(known).
library(pkident)
m <- pkpd_model(
"d/dt(depot) = -ka*depot
d/dt(central) = ka*depot - CL/V*central
cp = central/V",
outputs = "cp", # the concentration is measured
doses = bolus_dose("depot", "F*DOSE"), # a bolus into depot, of F x DOSE
known = "DOSE" # the dose is known; F is not
)An oral one-compartment model with unknown bioavailability
F. The dose reaching the system is F*DOSE, and
only DOSE is known.
2. Structure: can the parameters be determined at all?
<pkident structural identifiability>
Decision is LOCAL (Lie derivatives at the known initial state up to order 8, checked by output sensitivities; 5 random points).
Methods agree at 5 of 5 points.
CL combination_only
F combination_only
V combination_only
ka identifiable
Identifiable combinations:
CL/F
CL/V
Read the four words:
| Word | Meaning |
|---|---|
identifiable |
The data can determine the parameter by itself
(ka). |
combination_only |
The parameter cannot be separated, but a combination of it can
(CL, F, V; the combinations are
CL/F and CL/V). |
non_identifiable |
Neither the parameter nor a combination of it. |
unresolved |
The methods cannot decide; pkident says so instead of guessing. |
Here the concentration only ever shows F*DOSE through
V, so clearance and volume are determined only relative to
F. No amount of sampling changes this; only a different
experiment does, for example an intravenous dose given to the same
subjects, or knowing F. The decision is
local (at random points of the parameter space) and is
made only when two independent methods agree: Methods agree at 5 of
5 points.
3. Make F known and ask again
reference_model() has the model with F
known, among a set of textbook models checked against analytical results
(reference_models() lists them):
a3 <- reference_model("A3")
a3
structural_identifiability(a3)<pkident_model>
States: depot, central
Outputs: cp
Parameters: CL, V, ka
Known: DOSE
d/dt(depot) = -ka*depot; depot(0) = DOSE
d/dt(central) = ka*depot - CL*central/V; central(0) = 0
cp = central/V
<pkident structural identifiability>
Decision is LOCAL (Lie derivatives at the known initial state up to order 3, checked by output sensitivities; 5 random points).
Methods agree at 5 of 5 points.
CL identifiable
V identifiable
ka identifiable
All three parameters are identifiable. This is the best case: continuous, noise-free observation. Structural identifiability says it is possible; it does not say your samples are enough.
4. Design: how precisely, with these samples?
Give the parameter values you expect, the residual error of the
assay, and the sampling times. practical_identifiability()
returns the expected relative standard error (RSE) of each parameter
from the Fisher information:
values <- c(ka = 1, CL = 2, V = 20, DOSE = 100)
error <- residual_error(add = 0.05, prop = 0.1) # additive 0.05 plus 10% proportional
practical_identifiability(a3, design = c(0.5, 1, 2), values = values, error = error)<pkident practical identifiability>
Expected Fisher information for 1 individual(s), 3 observations each; LOCAL (linear) approximation.
Condition number (log scale): 36900
CL RSE 975.1% unresolved
V RSE 224.2% unresolved
ka RSE 257.2% unresolved
Note: some RSEs exceed 30%; the linear approximation is unreliable and the RSEs of all parameters may be underestimated. Examine likelihood profiles.
Weakest direction: +0.94 log(CL) -0.25 log(ka) -0.22 log(V) (expected SD on log scale 10.3)
Three samples in the first two hours see the absorption but hardly
the elimination, so the RSE of CL is 975%: the parameter is
determinable in principle (section 3) and not with this design. The
weakest direction names what the data cannot resolve here,
mostly log(CL). Samples out to 24 hours change that:
practical_identifiability(a3, design = c(0.5, 1, 2, 4, 6, 8, 12, 24), values = values, error = error)<pkident practical identifiability>
Expected Fisher information for 1 individual(s), 8 observations each; LOCAL (linear) approximation.
Condition number (log scale): 13.3
CL RSE 4.7% identifiable
V RSE 7.1% identifiable
ka RSE 14.6% identifiable
Weakest direction: +0.93 log(ka) +0.37 log(V) (expected SD on log scale 0.156)
unresolved here means the RSE is above the limit (30% by
default, rse_limit); identifiable means below.
The numbers are a linear approximation at the values you gave; when they
are above 30% treat them as a warning, not a measurement (the note says
so).
5. Compare candidate designs side by side
compare_designs() takes named candidates, each an
experiment(): sampling times, the dose, and the number of
individuals. It adds the structural status for what each one
observes:
compare_designs(
a3,
candidates = list(
early_3 = experiment(c(0.5, 1, 2), values = c(DOSE = 100)),
full_8 = experiment(c(0.5, 1, 2, 4, 6, 8, 12, 24), values = c(DOSE = 100)),
early_3_x12 = experiment(c(0.5, 1, 2), values = c(DOSE = 100), n = 12)
),
values = values, error = error
)<pkident design comparison>
Expected RSE (%) from the Fisher information; structural status for the observed outputs (LOCAL).
parameter early_3 full_8 early_3_x12
CL 975.1 4.7 281.5
V 224.2 7.1 64.7
ka 257.2 14.6 74.3
identifiable 0/3 3/3 0/3
Practically identifiable: RSE <= 30%.
Twelve individuals with the early design (early_3_x12)
bring the RSE of CL from 975% to 282%; one individual with
eight samples reaches 4.7%. When the design lacks late samples, more
subjects do not replace them. No design is optimised: you supply the
candidates and pkident reports each.
6. Where to go next
-
After a fit.
classify_profiles()takes an nlmixr2 fit and says, per parameter, whether the likelihood profile is bounded, one-sided, flat or shallow, and whether that is a property of the model (compared with the structural result) or of the data. - Case studies. Nimotuzumab target-mediated disposition, PSA follow-up for regrowth and reference models use these functions on real questions.
-
?pkpd_modelfor infusions, known input signals and PD models;as_table()turns any result into a data frame.